{"id":589,"date":"2019-01-24T09:25:27","date_gmt":"2019-01-24T07:25:27","guid":{"rendered":"https:\/\/phsites.technion.ac.il\/magnetic\/?page_id=589"},"modified":"2022-08-21T08:46:59","modified_gmt":"2022-08-21T06:46:59","slug":"experimental-metods","status":"publish","type":"page","link":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/","title":{"rendered":"Experimental methods"},"content":{"rendered":"<section class=\"gb-block-post-grid featuredpage aligncenter\"><div class=\"gb-post-grid-items is-grid columns-2\"><article id=\"post-85\" class=\"gb-post-grid-item post-85 page type-page status-publish has-post-thumbnail entry\"><div class=\"gb-block-post-grid-image\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/\" rel=\"bookmark\" aria-hidden=\"true\" tabindex=\"-1\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"203\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1-300x203.jpg\" class=\"attachment-medium size-medium\" alt=\"NMR\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1-300x203.jpg 300w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg 425w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div><div class=\"gb-block-post-grid-text\"><header class=\"gb-block-post-grid-header\"><h3 class=\"gb-block-post-grid-title\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/\" rel=\"bookmark\">NMR Nuclear Magnetic Resonance<\/a><\/h3><\/header><div class=\"gb-block-post-grid-excerpt\"><p>Our NMR apparatus is an hybridization of Oxford instruments TeslatronH magnet, Oxford instruments continuous flow cryostat, a TECMAG spectrometer, and a home built head. All systems are controlled by a MAC and experimental parameter such as magnetic field, temperature, frequency etc. can be modified automatically. The construction of this NMR laboratory was funded by: The&hellip;<\/p>\n<p><a class=\"gb-block-post-grid-more-link gb-text-link\" href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/\" rel=\"bookmark\">Continue Reading <span class=\"screen-reader-text\">NMR Nuclear Magnetic Resonance<\/span><\/a><\/p><\/div><\/div><\/article>\n<article id=\"post-105\" class=\"gb-post-grid-item post-105 page type-page status-publish has-post-thumbnail entry\"><div class=\"gb-block-post-grid-image\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nqr\/\" rel=\"bookmark\" aria-hidden=\"true\" tabindex=\"-1\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"205\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nqr_Amit-300x205.jpg\" class=\"attachment-medium size-medium\" alt=\"NQR\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nqr_Amit-300x205.jpg 300w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nqr_Amit.jpg 594w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div><div class=\"gb-block-post-grid-text\"><header class=\"gb-block-post-grid-header\"><h3 class=\"gb-block-post-grid-title\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nqr\/\" rel=\"bookmark\">NQR Nuclear Quadropole Resonance<\/a><\/h3><\/header><div class=\"gb-block-post-grid-excerpt\"><p>Our NQR apparatus is an hybridization of Oxford instruments continuous flow cryostat, a TECMAG spectrometer, and a home build head. All systems are controled by a PC under windows NT, and experimental parameter such as, temperature, frequency etc. can be modified automatically. The construction of this instrument was funded by: The French Israeli colaboration program&hellip;<\/p>\n<p><a class=\"gb-block-post-grid-more-link gb-text-link\" href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nqr\/\" rel=\"bookmark\">Continue Reading <span class=\"screen-reader-text\">NQR Nuclear Quadropole Resonance<\/span><\/a><\/p><\/div><\/div><\/article>\n<article id=\"post-114\" class=\"gb-post-grid-item post-114 page type-page status-publish has-post-thumbnail entry\"><div class=\"gb-block-post-grid-image\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/musr\/\" rel=\"bookmark\" aria-hidden=\"true\" tabindex=\"-1\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"203\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/musr_2-300x203.jpg\" class=\"attachment-medium size-medium\" alt=\"MUSR\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/musr_2-300x203.jpg 300w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/musr_2.jpg 423w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div><div class=\"gb-block-post-grid-text\"><header class=\"gb-block-post-grid-header\"><h3 class=\"gb-block-post-grid-title\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/musr\/\" rel=\"bookmark\">MuSR &#8211; Muon Spin Relaxation<\/a><\/h3><\/header><div class=\"gb-block-post-grid-excerpt\"><p>In order to have muon beam we travel to either ISIS or PSI where we perform longitudinal and transverse field mSR experiments. The data collected in these experiment are imported into Origin for analysis. The experiment&#8217;s data are imported into Origin worksheets and brought home for analysis. We have developed specialized macros under Origin, which&hellip;<\/p>\n<p><a class=\"gb-block-post-grid-more-link gb-text-link\" href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/musr\/\" rel=\"bookmark\">Continue Reading <span class=\"screen-reader-text\">MuSR &#8211; Muon Spin Relaxation<\/span><\/a><\/p><\/div><\/div><\/article>\n<article id=\"post-150\" class=\"gb-post-grid-item post-150 page type-page status-publish has-post-thumbnail entry\"><div class=\"gb-block-post-grid-image\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/susceptibility\/\" rel=\"bookmark\" aria-hidden=\"true\" tabindex=\"-1\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"200\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/ZaherAmit-300x200.jpg\" class=\"attachment-medium size-medium\" alt=\"Zaher Salman and Amit Kanigel.\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/ZaherAmit-300x200.jpg 300w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/ZaherAmit.jpg 422w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div><div class=\"gb-block-post-grid-text\"><header class=\"gb-block-post-grid-header\"><h3 class=\"gb-block-post-grid-title\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/susceptibility\/\" rel=\"bookmark\">Susceptibility<\/a><\/h3><\/header><div class=\"gb-block-post-grid-excerpt\"><p>Our new dc magnetometer was purchased from Cryogenic. The temperature range is 1.2 to 300 and field up to 6.5T. A furnace installation is on the way. It has two magnet power supplies one for low fields (&lt;200G) where it can work with mG resolution. It also has two channels for measuring magnetization in two&hellip;<\/p>\n<p><a class=\"gb-block-post-grid-more-link gb-text-link\" href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/susceptibility\/\" rel=\"bookmark\">Continue Reading <span class=\"screen-reader-text\">Susceptibility<\/span><\/a><\/p><\/div><\/div><\/article>\n<article id=\"post-163\" class=\"gb-post-grid-item post-163 page type-page status-publish has-post-thumbnail entry\"><div class=\"gb-block-post-grid-image\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/dilution-refrigerator\/\" rel=\"bookmark\" aria-hidden=\"true\" tabindex=\"-1\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"209\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/dr_FirstCool-300x209.jpg\" class=\"attachment-medium size-medium\" alt=\"Dilution Refrigerator, First Cool\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/dr_FirstCool-300x209.jpg 300w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/dr_FirstCool-1024x714.jpg 1024w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/dr_FirstCool.jpg 1100w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/div><div class=\"gb-block-post-grid-text\"><header class=\"gb-block-post-grid-header\"><h3 class=\"gb-block-post-grid-title\"><a href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/dilution-refrigerator\/\" rel=\"bookmark\">Dilution Refrigerator<\/a><\/h3><\/header><div class=\"gb-block-post-grid-excerpt\"><p>This picture was taken during the installation period of our Oxford Kelvinox dilution refrigerator.This refrigerator will allow us to perform NMR and transport measurements in sub-Kelvin temperatures.From left to right:Amit Kanigal, Eva Segal, Oren Shafir and Mordeci Eilon. On first cool down we reached 28mK. The guys are very happy.From left to right: Rinat Assa,&hellip;<\/p>\n<p><a class=\"gb-block-post-grid-more-link gb-text-link\" href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/dilution-refrigerator\/\" rel=\"bookmark\">Continue Reading <span class=\"screen-reader-text\">Dilution Refrigerator<\/span><\/a><\/p><\/div><\/div><\/article>\n<\/div><\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"class_list":{"0":"post-589","1":"page","2":"type-page","3":"status-publish","5":"entry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Experimental methods - Magnetism Group<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Experimental methods - Magnetism Group\" \/>\n<meta property=\"og:url\" content=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/\" \/>\n<meta property=\"og:site_name\" content=\"Magnetism Group\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-21T06:46:59+00:00\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/\",\"url\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/\",\"name\":\"Experimental methods - Magnetism Group\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/#website\"},\"datePublished\":\"2019-01-24T07:25:27+00:00\",\"dateModified\":\"2022-08-21T06:46:59+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Experimental methods\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/#website\",\"url\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/\",\"name\":\"Magnetism Group\",\"description\":\"Prof. Amit Keren&#039;s Group - Technion\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Experimental methods - Magnetism Group","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/","og_locale":"en_US","og_type":"article","og_title":"Experimental methods - Magnetism Group","og_url":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/","og_site_name":"Magnetism Group","article_modified_time":"2022-08-21T06:46:59+00:00","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/","url":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/","name":"Experimental methods - Magnetism Group","isPartOf":{"@id":"https:\/\/phsites.technion.ac.il\/magnetic\/#website"},"datePublished":"2019-01-24T07:25:27+00:00","dateModified":"2022-08-21T06:46:59+00:00","breadcrumb":{"@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/phsites.technion.ac.il\/magnetic\/"},{"@type":"ListItem","position":2,"name":"Experimental methods"}]},{"@type":"WebSite","@id":"https:\/\/phsites.technion.ac.il\/magnetic\/#website","url":"https:\/\/phsites.technion.ac.il\/magnetic\/","name":"Magnetism Group","description":"Prof. Amit Keren&#039;s Group - Technion","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/phsites.technion.ac.il\/magnetic\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"featured_image_src":null,"featured_image_src_square":null,"_links":{"self":[{"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/pages\/589","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/comments?post=589"}],"version-history":[{"count":0,"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/pages\/589\/revisions"}],"wp:attachment":[{"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/media?parent=589"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}