{"id":85,"date":"2015-03-11T13:05:23","date_gmt":"2015-03-11T11:05:23","guid":{"rendered":"http:\/\/phsites.technion.ac.il\/magnetic\/?page_id=85"},"modified":"2022-08-21T08:44:37","modified_gmt":"2022-08-21T06:44:37","slug":"nmr","status":"publish","type":"page","link":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/","title":{"rendered":"NMR Nuclear Magnetic Resonance"},"content":{"rendered":"\n<p> Our NMR apparatus is an hybridization of <a rel=\"noreferrer noopener\" href=\"http:\/\/www.oxford-instruments.com\/\" target=\"_blank\">Oxford instruments<\/a> TeslatronH magnet, <a rel=\"noreferrer noopener\" href=\"http:\/\/www.oxford-instruments.com\/\" target=\"_blank\">Oxford instruments<\/a> continuous flow cryostat, a <a rel=\"noreferrer noopener\" href=\"http:\/\/www.tecmag.com\/\" target=\"_blank\">TECMAG<\/a> spectrometer, and a home built head. All systems are controlled by a MAC and experimental parameter such as magnetic field, temperature, frequency etc. can be modified automatically. <\/p>\n\n\n\n<p> The construction of this NMR laboratory was funded by: <\/p>\n\n\n\n<ul class=\"wp-block-list\"><li> <a rel=\"noreferrer noopener\" href=\"http:\/\/www.academy.ac.il\/\" target=\"_blank\">The Israeli Academy of Science<\/a> (heavy equipment).<\/li><li>Crown center for superconductivity.<\/li><li>The <a rel=\"noreferrer noopener\" href=\"http:\/\/www.technion.ac.il\/\" target=\"_blank\">Technion<\/a> new staff support. <\/li><\/ul>\n\n\n\n<p> Instrument Scientist:<br>Oren Ofer <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"> Magnet <\/h3>\n\n\n\n<div class=\"wp-block-genesis-blocks-gb-columns gb-layout-columns-2 gb-2-col-equal\"><div class=\"gb-layout-column-wrap gb-block-layout-column-gap-2 gb-is-responsive-column\">\n<div class=\"wp-block-genesis-blocks-gb-column gb-block-layout-column\"><div class=\"gb-block-layout-column-inner\">\n<p>The leads of the magnets are permanently connected and the field can be swept from zero to 9T in 1G steps. The homogeneity is 2ppm in 1cm3 and no shimming coils are installed.<\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-genesis-blocks-gb-column gb-block-layout-column\"><div class=\"gb-block-layout-column-inner\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"425\" height=\"288\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg\" alt=\"NMR\" class=\"wp-image-95\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg 425w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1-300x203.jpg 300w\" sizes=\"auto, (max-width: 425px) 100vw, 425px\" \/><figcaption>A. Keren is acting as if he is doing something<\/figcaption><\/figure>\n<\/div><\/div><\/div>\n<\/div><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"> Cryostat <\/h3>\n\n\n\n<p> The <a rel=\"noreferrer noopener\" href=\"http:\/\/www.oxford-instruments.com\/\" target=\"_blank\">Oxford instruments<\/a> continuous flow cryostat (CF1200 daynamic) allows a working temperature ranging from 1.6 to 450K, and a 62mm sample space diameter. <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_Cryostat.jpg\" alt=\"nmr Cryostat\" class=\"wp-image-97\" width=\"425\" height=\"263\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_Cryostat.jpg 425w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_Cryostat-300x186.jpg 300w\" sizes=\"auto, (max-width: 425px) 100vw, 425px\" \/><figcaption>G. Bazalitsky transferring N2, Z. Salman is analyzing\ndata and A. Keren is looking for a signal.<\/figcaption><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"> Spectrometer <\/h3>\n\n\n\n<div class=\"wp-block-genesis-blocks-gb-columns gb-layout-columns-2 gb-2-col-equal\"><div class=\"gb-layout-column-wrap gb-block-layout-column-gap-2 gb-is-responsive-column\">\n<div class=\"wp-block-genesis-blocks-gb-column gb-block-layout-column\"><div class=\"gb-block-layout-column-inner\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"421\" height=\"281\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_GalinaZaher.jpg\" alt=\"at the lab\" class=\"wp-image-98\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_GalinaZaher.jpg 421w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_GalinaZaher-300x200.jpg 300w\" sizes=\"auto, (max-width: 421px) 100vw, 421px\" \/><figcaption>Z. Salman and G. Bazalitsky working and working and working and working. <\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-genesis-blocks-gb-column gb-block-layout-column\"><div class=\"gb-block-layout-column-inner\">\n<p>The spectrometer is single channel. It is constructed from TECMAG NMRKit-II as a transmitter and receiver, and LIBRA as a pulse programmer and ADC. It uses a PTS-310 frequency synthesizer, and AMT 1KW power supply. Currently we are capable of working between 6-220 MHz due to the AMT frequency range.<\/p>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Head<\/h3>\n\n\n\n<p> The head is made of series-parallel tank circuit using Cylindrical Teflon capacitors. The capacitance can be varied from the top of the cryostat. In order to load a sample the head must be removed from the cryostat. <\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"423\" height=\"286\" src=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_4.jpg\" alt=\"\" class=\"wp-image-100\" srcset=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_4.jpg 423w, https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_4-300x203.jpg 300w\" sizes=\"auto, (max-width: 423px) 100vw, 423px\" \/><figcaption>Z. Salman is changing sample.<\/figcaption><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\"> Origin <\/h3>\n\n\n\n<p> Origin 7.0 The experiment&#8217;s data are imported into Origin worksheets and brought home for analysis. We have developed specialized macros under Origin for NMR data analysis. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\"> Programer: <\/h4>\n\n\n\n<p> Galina Bazalitsky <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"> NMR Publications: <\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>A. Keren, <a href=\"http:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/Keren_PRB_99.pdf\">Spin echo decay in a stochastic field environment<\/a>, Phys. Rev. B 60, 9279 (1999).<\/li><\/ul>\n\n\n\n<p>Abstract:<br>We derive a general formalism with which it is possible to obtain the time t dependence of the echo size for a spin in a tochastic field environment. Our model is based on &#8221;strong collisions&#8221;. We examine in detail two examples. In the first one the field distribution has a finite second moment, and in the second one (a Lorentzian) it does not. We find that the echo decay in the first case is exponential in t<sup>3<\/sup> as t-&gt;0, and in the second case can be approximated by the phenomenological expression exp (-[2t\/T<sub>2<\/sub>]<sup>b<\/sup>) with 10 limit b =2. In addition, only the first case shows a T<sub>2<\/sub> minimum effect.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Our NMR apparatus is an hybridization of Oxford instruments TeslatronH magnet, Oxford instruments continuous flow cryostat, a TECMAG spectrometer, and a home built head. All systems are controlled by a MAC and experimental parameter such as magnetic field, temperature, frequency etc. can be modified automatically. The construction of this NMR laboratory was funded by: The [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":95,"parent":589,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"class_list":{"0":"post-85","1":"page","2":"type-page","3":"status-publish","4":"has-post-thumbnail","6":"entry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>NMR Nuclear Magnetic Resonance - Magnetism Group<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"NMR Nuclear Magnetic Resonance - Magnetism Group\" \/>\n<meta property=\"og:description\" content=\"Our NMR apparatus is an hybridization of Oxford instruments TeslatronH magnet, Oxford instruments continuous flow cryostat, a TECMAG spectrometer, and a home built head. All systems are controlled by a MAC and experimental parameter such as magnetic field, temperature, frequency etc. can be modified automatically. The construction of this NMR laboratory was funded by: The [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/\" \/>\n<meta property=\"og:site_name\" content=\"Magnetism Group\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-21T06:44:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"425\" \/>\n\t<meta property=\"og:image:height\" content=\"288\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/nmr\\\/\",\"url\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/nmr\\\/\",\"name\":\"NMR Nuclear Magnetic Resonance - Magnetism Group\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/nmr\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/nmr\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/wp-content\\\/uploads\\\/sites\\\/26\\\/2015\\\/03\\\/nmr_1.jpg\",\"datePublished\":\"2015-03-11T11:05:23+00:00\",\"dateModified\":\"2022-08-21T06:44:37+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/nmr\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/nmr\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/nmr\\\/#primaryimage\",\"url\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/wp-content\\\/uploads\\\/sites\\\/26\\\/2015\\\/03\\\/nmr_1.jpg\",\"contentUrl\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/wp-content\\\/uploads\\\/sites\\\/26\\\/2015\\\/03\\\/nmr_1.jpg\",\"width\":425,\"height\":288,\"caption\":\"A. Keren is acting as if he is doing something\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/nmr\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Experimental methods\",\"item\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/experimental-metods\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"NMR Nuclear Magnetic Resonance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/#website\",\"url\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/\",\"name\":\"Magnetism Group\",\"description\":\"Prof. Amit Keren&#039;s Group - Technion\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/phsites.technion.ac.il\\\/magnetic\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"NMR Nuclear Magnetic Resonance - Magnetism Group","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/","og_locale":"en_US","og_type":"article","og_title":"NMR Nuclear Magnetic Resonance - Magnetism Group","og_description":"Our NMR apparatus is an hybridization of Oxford instruments TeslatronH magnet, Oxford instruments continuous flow cryostat, a TECMAG spectrometer, and a home built head. All systems are controlled by a MAC and experimental parameter such as magnetic field, temperature, frequency etc. can be modified automatically. The construction of this NMR laboratory was funded by: The [&hellip;]","og_url":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/","og_site_name":"Magnetism Group","article_modified_time":"2022-08-21T06:44:37+00:00","og_image":[{"width":425,"height":288,"url":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg","type":"image\/jpeg"}],"twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/","url":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/","name":"NMR Nuclear Magnetic Resonance - Magnetism Group","isPartOf":{"@id":"https:\/\/phsites.technion.ac.il\/magnetic\/#website"},"primaryImageOfPage":{"@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/#primaryimage"},"image":{"@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/#primaryimage"},"thumbnailUrl":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg","datePublished":"2015-03-11T11:05:23+00:00","dateModified":"2022-08-21T06:44:37+00:00","breadcrumb":{"@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/#primaryimage","url":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg","contentUrl":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg","width":425,"height":288,"caption":"A. Keren is acting as if he is doing something"},{"@type":"BreadcrumbList","@id":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/nmr\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/phsites.technion.ac.il\/magnetic\/"},{"@type":"ListItem","position":2,"name":"Experimental methods","item":"https:\/\/phsites.technion.ac.il\/magnetic\/experimental-metods\/"},{"@type":"ListItem","position":3,"name":"NMR Nuclear Magnetic Resonance"}]},{"@type":"WebSite","@id":"https:\/\/phsites.technion.ac.il\/magnetic\/#website","url":"https:\/\/phsites.technion.ac.il\/magnetic\/","name":"Magnetism Group","description":"Prof. Amit Keren&#039;s Group - Technion","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/phsites.technion.ac.il\/magnetic\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"featured_image_src":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg","featured_image_src_square":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-content\/uploads\/sites\/26\/2015\/03\/nmr_1.jpg","_links":{"self":[{"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/pages\/85","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/comments?post=85"}],"version-history":[{"count":0,"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/pages\/85\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/pages\/589"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/media\/95"}],"wp:attachment":[{"href":"https:\/\/phsites.technion.ac.il\/magnetic\/wp-json\/wp\/v2\/media?parent=85"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}